DEWTRON250
Effectively avoiding interference and erosion of oil molecular
High corrosion resistance, sensor poison immunity
Feature
Using nanoscale oil-repellent filters to overcome the issue of oil and gas carryover affecting sensors in the hydrogen system.
Directly measure the humidity of gases such as H2, SF6, H2S, CO2, chlorine, acetic acid, bromine vapor, and other gases.
Technical Parameter
Measuring Range | Depoint -100°C~+20°C or -80°C~+60°C |
Accuracy | Less than ±1,0°C with dewpoint – 65°C~+20°C range |
Resolution | Dewpoint 0.1°C or 1ppm |
Unit | Dewpoint °C、°F、ppm、g/m3 |
Operating Temparature | ≤70℃ |
Operating Pressure | ≤1.5MPa |
Power Rating | 220VAC или 24VDC /4 W |
Alarm Signal | SPDT mode |
Output Capacity | 250V/5A |
Signal Output | 4-20mA |
Ex. mark | Exd IIC T6 Gb |
We focus on research and innovations
International high-tech company
We will recommend you the most suitable option according to your working conditions.
Send request