Products

ZZCG-100(A)

ZZCG-100(A) Laser Methane Extraction Pipeline Comprehensive Parameter Wireless Monitoring Device

Product Description

The ZZCG-100(A) Laser Methane Extraction Pipeline Comprehensive Parameter Wireless Monitoring Device is a precision instrument used to measure gas flow, methane concentration, carbon monoxide concentration, pipeline pressure, and gas temperature during the gas extraction process.

Product Description

The ZZCG-100(A) Laser Methane Extraction Pipeline Comprehensive Parameter Wireless Monitoring Device is a precision instrument used to measure gas flow, methane concentration, carbon monoxide concentration, pipeline pressure, and gas temperature during the gas extraction process.

Feature

  • The monitoring device can display real-time values of five parameters on the same screen: flow rate, methane concentration, carbon monoxide concentration, temperature, and pipeline pressure. It can also show accumulated mixed gas and pure gas quantities over a specified period.
  • The device has a self-diagnosis function for anomalies, including communication errors and disconnection indicators. It can intelligently analyze and assess the status of sensors based on parameters such as methane concentration, pressure, and temperature, providing anomaly alerts.
  • The monitoring device supports wireless communication, enabling data transmission via wireless networks to handheld terminals.
  • It can automatically form communication networks with multiple devices and wirelessly transmit data to underground wireless base stations.
  • Methane concentration is measured using laser technology, which is unaffected by water vapor and other impurity gases. The measurement includes negative pressure compensation, ensuring accurate methane concentration readings in high negative pressure environments.
  • The flow sensor uses an insertion installation method, which is non-obstructive and requires only a small hole in the pipeline for installation.

Technical parameter

Parameter Measurement Range Accuracy
Flow Rate (0.0~100.0) m³/min Within ±1.5% FS
Methane (0.00~100.0)% CH₄ (0.00~1.0)% CH₄: Within ±0.05% CH₄

(1.0~100)% CH₄: Within ±5.0% of the actual value

   
Absolute Pressure (10.0~200.0) kPa Within ±0.75% FS
Temperature (-10.0~60.0)℃ Within ±1℃
Carbon Monoxide (0~1000)×10⁻⁶

(expandable to 0~2000)×10⁻⁶

(0~100)×10⁻⁶: Within ±4×10⁻⁶

(>100~500)×10⁻⁶: Within ±5.0% of the actual value

>500×10⁻⁶: Within ±6.0% of the actual value

Signal Mode

  •  Wired Mode: RS485
  • Wireless Mode: Bluetooth

 

Notes

  • The GTH1000 carbon monoxide sensor for coal mines can be configured according to user requirements.
  • The signal format can be customized to include one or multiple options based on user needs.

We focus on research and innovations

International high-tech company

*
*

Application

Receiving requests

We will recommend you the most suitable option according to your working conditions.

*
*

WhatsApp

8615003875985

       

E-mail

[email protected]

Online

Message

Top