In accordance with Article 79 of the "Coal Mine Fire Prevention and Extinguishment Regulations," it is mandatory to establish a comprehensive observation system for sealed areas. Regular measurements must be conducted to determine the pressure difference inside and outside the sealed area, as well as the concentrations of methane, oxygen, carbon monoxide, carbon dioxide, and air temperature. This facilitates air leakage analysis and helps in understanding the spontaneous combustion trends within the sealed area. The multi-parameter monitoring device for mining enclosed spaces is designed for gas monitoring and intelligent extraction in coal mine enclosed spaces (such as goafs). It incorporates advanced technologies such as laser gas detection, wireless transmission, data analysis, and intelligent control, providing a comprehensive solution for precise fire monitoring, intelligent early warning, and extraction regulation in coal mine enclosed spaces (goafs).
Product Description
In accordance with Article 79 of the “Coal Mine Fire Prevention and Extinguishment Regulations,” it is mandatory to establish a comprehensive observation system for sealed areas. Regular measurements must be conducted to determine the pressure difference inside and outside the sealed area, as well as the concentrations of methane, oxygen, carbon monoxide, carbon dioxide, and air temperature. This facilitates air leakage analysis and helps in understanding the spontaneous combustion trends within the sealed area. The multi-parameter monitoring device for mining enclosed spaces is designed for gas monitoring and intelligent extraction in coal mine enclosed spaces (such as goafs). It incorporates advanced technologies such as laser gas detection, wireless transmission, data analysis, and intelligent control, providing a comprehensive solution for precise fire monitoring, intelligent early warning, and extraction regulation in coal mine enclosed spaces (goafs).
Features
Technical Parameter
Parameter | Measurement Range | Basic Error | |
CH4 | (0.00~100.0)% | (0.00 ~ 1.00)% (1.00 ~ 100.0)% |
±0.05% ±5% of the true value |
CO2 | (0.00~5.00)% | (0.00 ~ 0.50)% (0.50 ~ 5.00)% |
±0.10% ±(0.05+5%of the true value) |
CO | (0~500)x10-6 | (0 ~ 100)×10-6 (>100 ~ 500)×10-6 |
±4×10-6 ±5% of the true value |
O2 | (0.0~25.0)% | (0.0 ~ 25.0)% | ±0.8% |
H2S | (0~50)x10-6 | (0 ~ 50)×10-6 | ±3×10-6 |
(50~200)x10-6 | (50 ~ 200)×10-6 | ±10% of the true value | |
C2H4 | (0~200)x10-6 | (0 ~ 2)×10-6 (>2 ~ 5)×10-6 (>5 ~ 100)×10-6 (>100 ~ 200)×10-6 |
±0.5×10-6 ±1×10-6 ±2×10-6 ±10×10-6 |
C2H2 | (0.0~1000.0)x10-6 | (0.0 ~ 2.0)×10-6 (>2.0 ~ 5.0)×10-6 (>5.0 ~ 100.0)×10-6 (>100.0 ~ 500.0)×10-6 (>500.0 ~ 1000.0)×10-6 |
±0.5×10-6 ±1×10-6 ±2×10-6 ±10×10-6 ±2%FS |
Temperature | (-10.0 ~ 70.0)℃ | (-10.0 ~ 70.0) | ±1℃ |
Humidity | (10 ~ 95)%RH | (10 ~ 95)%RH | ±5%RH |
Smoke | ≥5% obs/m Alarm | ||
Pressure Difference | (-5.00 ~ 5.00)kPa | Negative Pressure: (-5.00 ~ 0.00)kPa | ±0.1kPa |
Positive Pressure: (0.00 ~ 5.00)kPa |